1.
Radiat Res ; 200(6): 569-576, 2023 Dec 01.
Article in English | MEDLINE | ID: mdl-37931289

ABSTRACT

In this study, the preparation and characterization of copper (Cu) and terbium (Tb) co-doped lithium borate glass using spectroscopic and thermoluminescence techniques are reported. A thermal treatment was introduced to increase the degree of crystallinity. The thermoluminescence glow curve signal of the samples displayed upon exposure to beta radiation was measured and analyzed. It was found that the samples doped with 0.1% of copper and co-doped with 0.3% terbium showed the highest thermoluminescent (TL) signal in response to the irradiated dose. The analyses revealed that the glow curves of the doped samples were composed of nine overlapping glow peaks with activation energies between 0.73 and 2.78 eV. As a whole area under the glow curve, the TL signals displayed a linear dose response in the range from 110 mGy to 55 Gy. The minimum detectible dose of the samples was found to be 10.39 µGy. It was found that peaks 1 and 2 disappear after one day of storage. The rest of the peaks (3-9) remain almost constant up to 74 days of storage.


Subject(s)
Copper , Terbium , Copper/chemistry , Terbium/chemistry , Thermoluminescent Dosimetry/methods
2.
Appl Radiat Isot ; 191: 110533, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36332424

ABSTRACT

A potentially tissue-equivalent dosimeter based on lithium tetraborate co-doped with Cu and In was successfully synthesized in two steps melting process. Basic material properties were characterized using Differential scanning calorimetry, X-ray diffraction, and Fourier Transform Infrared Spectroscopy, the dosimetric properties using Thermoluminescence. The highest sensitivity was observed for dopant concentrations of 0.1% Cu and 0.5% In. Tmax-Tstop analysis revealed the existence of eight individual peaks in the composite TL glow curve, which was confirmed by computerized glow curve deconvolution. A linear dose-response was seen up to about 30 Gy, for higher doses saturation effects occurred. The minimum detectable dose was estimated at about 670 µGy. TL peaks, with peak temperature above 150 °C faded to values between 3.3 and 14.9% of the respective of initial values after 70 days storage.


Subject(s)
Borates , Thermoluminescent Dosimetry , Thermoluminescent Dosimetry/methods , Borates/chemistry , X-Ray Diffraction , Radiometry